Resetting to Factory Default Settings

If the device no longer functions as expected, you can choose to reset the device to its factory default settings.

Use the firmware revert button to reset the device. The firmware revert button is shown in the following diagram:

Note: Be careful not to scratch the dome bubble.

Figure 2: The firmware revert button between the status LEDs.

  1. Ensure the camera is powered on.
  2. Remove the dome cover by loosening the screws that fix the cover to the base. The Torx key included with the dome camera can be used to loosen the screws
  3. Using a straightened paperclip or similar tool, gently press and hold the firmware revert button for two seconds.
  4. Re-install the dome cover.

CAUTION — Do not apply excessive force. Inserting the tool too far may damage the camera.